Functional Description
5.4
Overvoltage Protection
The BTC50010-1TAA provides Infineon® SMART CLAMPING functionality, which suppresses over voltages by
actively clamping the overvoltage across the power stage and the load. This is achieved by controlling the clamp
voltage VDS(CL) depending on the junction temperature TJ and the load current IL.
5.5
Protection during Loss of Load or Loss of VS Condition
In case of loss of VS with charged line inductances, the maximum supply voltage has to be limited. It is
recommended to use a diode and a Z-diode (VZ1 + VD1 < 16V, please refer to Figure 12).
by case
Loss of Vs
Vbat
External
components D1
according to
either A or B is Z1
required, not
both
VIN
A
VD1
VZ1
RIN
Module
RVS
IN
Module Ground
VS
B
R/L cable
VD1
D1
VZ1 Z1
Load
Ground
R/L cable
Figure 12 External Component for BTC50010-1TAA Loss of VS Protection
In case of loss of load with charged primary power line inductances, the maximum supply voltage also has to be
limited. It is recommended to use a Z-diode (VZ2 < 28V) or VS clamping power switches between VS and Module
Ground (please refer to Figure 13).