BTC50010-1TAA
General Product Characteristics
2. Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as “outside” normal operating range. Protection functions are not
designed for continuous repetitive operation.
4.2
Functional Range
Table 3 Functional Range
TJ = 25 °C, all voltages and currents refer to definitions in Figure 4 (unless otherwise specified).
Parameter
Symbol
Values
Unit Note /
Min. Typ. Max.
Test Condition
Number
Nominal operating voltage
Extended static operating
voltage
VS_OP
8
VS_OP_EXT 5
–
18
V
–
P_4.2.1
–
28
V
1) 2) IL ≤ IL(NOM)
P_4.2.2
Extended operating voltage VS_DYN
3.2
–
contain dynamic
undervoltage capability
28
V
1) VS decreasing P_4.2.3
according to
ISO7637
according to LV124
Static undervoltage level
VS_UV
–
(start of loss of functionality)
–
4.5
V
RL=270 Ω
P_4.2.4
VS decreasing
VDS ≤ 0.5 V
ICP_ON = 0 µA
Figure 5
Undervoltage restart level
static
VS_UV_Restart –
–
5
V
RL=270 Ω
VS increasing
VDS ≤ 0.5 V
ICP_ON = 0 µA
Figure 5
P_4.2.5
Charge pump current in ON
state (maximum allowed
leakage current at CP pin)
ICP_ON
0
2
µA VIN = 0 V, t > tON P_4.2.6
Maximum allowed Current in IIN_OFF
–
OFF state
IN pins High
–
30
µA Pull-up current flow P_4.2.7
through internal
current source
1) Not subject to production test, specified by design.
2) Within the range of VS_OP_EXT and out of the range of VS_OP, device parameter deviation is possible.
Note: Within the functional range the IC operates as described in the circuit description. The electrical
characteristics are specified within the conditions given in the related electrical characteristics table.