DC Operating Characteristics for Inputs and Outputs
Unless otherwise specified, the table below lists the 3.3V/1.8 V DC operating characteristics of the ICS1894-32
inputs and outputs.
For 3.3 V Signals
Parameter
Input High Voltage
Input Low Voltage
Output High Voltage
Output Low Voltage
For 1.8 V Signals
Symbol
VIH
VIL
VOH
VOL
Conditions
IOH = –4 mA
IOL = +4 mA
Min. Max. Units
2.0 –
V
– 0.8 V
2.4 –
V
– 0.4 V
Parameter
Input High Voltage
Input Low Voltage
Output High Voltage
Output Low Voltage
Symbol
VIH
VIL
VOH
VOL
Conditions
IOH = –4 mA
IOL = +4 mA
Min. Max. Units
0.8 –
V
– 0.7 V
1.6 –
V
– 0.1 V