APPENDIX
SECTOR PROTECTION/UNPROTECTION
USING PROGRAMMING EQUIPMENT
In addition to in-situ sector protection/unprotec-
tion, described in the Bus Operations section, the
HY29LV160 is capable of performing the same
functions using programming equipment. This
appendix describes the procedures and provides
specifications for these functions.
Sector Protect
The hardware sector protection feature disables
both program and erase operations in any sector
or combination of sectors.
The method intended for programming equipment
requires a high voltage (VID) on address pin A[9]
and the OE# pin. The flow chart in Figure A1 il-
lustrates the algorithm, and timing specifications
and waveforms are provided at the end of this sec-
tion. When implementing the algorithm, note that
VCC must be applied to the device before applying
VID, and VID should be removed before removing
VCC from the device.
Programming of the protection circuitry begins on
the falling edge of WE# and is terminated on the
rising edge of the same pulse. Verification of pro-
tection is done as described in the Electronic ID
Mode section and shown in the flow chart.
The HY29LV160 is shipped with all sectors un-
protected.
Sector Unprotect
The hardware sector unprotection feature re-en-
ables both program and erase operations in pre-
viously protected sectors. Note that to unprotect
any sector, all unprotected sectors must first be
protected prior to the first sector unprotect write
cycle.
The method intended for programming equipment
requires a high voltage (VID) on address pin A[9]
and the OE# pin. The flow chart in Figure A2 illus-
trates the algorithm, and timing specifications and
waveforms are given at the end of this section.
When implementing the algorithm, note that VCC
must be applied to the device before applying VID,
and VID should be removed before removing VCC
from the device.
DC CHARACTERISTICS
Sector Protection and Unprotection Using Programming Equipment
Parameter
Description
Test Conditions
Min
Max Unit
VCC Operating Power Supply
VID
Voltage for Sector Protect, Unprotect
and Verify
VCC = 3.0 V
3.0
3.6
V
11.5
12.5
V
ILIT
High Voltage Input Load Current
(A[9], OE#)
VCC = VCC Max
A[9] = OE# = 12.5 V
35
µA
VIL
Input Low Voltage
VIH Input High Voltage
-0.5
0.8
V
2.0 VCC + 0.5 V
Sector Protection and Unprotection Verification Using Programming Equipment 1
Operation
CE# OE# WE# RESET# A[19:12] A[9] A[6] A[1] A[0] DQ[7:0]
Sector Protect Verification
Sector Unprotect Verification
L LH
L
H
Sector
Address
VID
HL
H
0x01
0x00
Notes:
1. L = V , H = V .
IL
IH
42