English
Language : 

HY29LV160 Datasheet, PDF (37/48 Pages) Hynix Semiconductor – 16 Mbit (2M x 8/1M x 16) Low Voltage Flash Memory
AC CHARACTERISTICS
HY29LV160
Alternate CE# Controlled Erase/Program Operations
Parameter
JEDEC Std
Description
Speed Option
Unit
- 70 - 80 - 90 - 12
tAVAV
tAVEL
tELAX
tDVEH
tEHDX
tGHEL
tWLEL
tEHWH
tELEH
tEHEL
tWC Write Cycle Time 1
tAS Address Setup Time
tAH Address Hold Time
tDS Data Setup Time
tDH Data Hold Time
tGHEL Read Recovery Time Before Write
tWS WE# Setup Time
tWH WE# Hold Time
tCP CE# Pulse Width
tCPH CE# Pulse Width High
tWHWH1 tWHWH1 Programming Operation 1, 2, 3
Chip Programming Operation 1, 2, 3, 5
Min 70 80 90 120 ns
Min
0
ns
Min 45 45 45 50 ns
Min 35 35 45 50 ns
Min
0
ns
Min
0
ns
Min
0
ns
Min
0
ns
Min 35 35 35 50 ns
Min
30
ns
Typ
9
µs
Byte Mode
Max
300
µs
Word Typ
18
µs
Mode Max
500
µs
Typ
18
sec
Byte Mode
Max
54
sec
Word Typ
18
sec
Mode Max
54
sec
tWHWH2 tWHWH2 Sector Erase Operation 1, 2, 4
Typ
0.25
sec
Max
5
sec
tWHWH3
tWHWH3 Chip Erase Operation 1, 2, 4
Erase and Program Cycle Endurance 1
Typ
8
sec
Typ
1,000,000
cycles
Min
100,000
cycles
tBUSY CE# to RY/BY# Delay
Min
90
ns
Notes:
1. Not 100% tested.
2. Typical program and erase times assume the following conditions: 25 °C, VCC = 3.0 volts, 100,000 cycles. In addition,
programming typicals assume a checkerboard pattern. Maximum program and erase times are under worst case condi-
tions of 90 °C, VCC = 2.7 volts (3.0 volts for 70 ns version), 100,000 cycles.
3. Excludes system-level overhead, which is the time required to execute the four-bus-cycle sequence for the program
command. See Table 6 for further information on command sequences.
4. Excludes 0x00 programming prior to erasure. In the preprogramming step of the Automatic Erase algorithm, all bytes
are programmed to 0x00 before erasure.
5. The typical chip programming time is considerably less than the maximum chip programming time listed since most
bytes program faster than the maximum programming times specified. The device sets DQ[5] = 1 only If the maximum
byte program time specified is exceeded. See Write Operation Status section for additional information.
Rev. 1.2/May 01
37