RFM42 Datasheet, PDF (67/110 Pages) –
RFM42/43
Register 12h. Temperature Sensor Calibration
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
tsrange[1:0]
entsoffs
entstrim
tstrim[3:0]
Type
R/w
R/w
R/w
R/w
Reset value = 00100000
Bit
7:6
5
4
3:0
Name
tsrange[1:0]
entsoffs
entstrim
tstrim[3:0]
Function
Temperature Sensor Range Selection.
(FS range is 0..1024 mV)
00: –40℃ .. 64℃ (full operating range), with 0.5℃ resolution (1 LSB in
the 8-bit ADC)
01: –40℃… 85℃, with 1℃ resolution (1 LSB in the 8-bit ADC)
11: 0 ℃ …85℃, with 0.5℃ resolution (1 LSB in the 8-bit ADC)
10: –40o F … 216o F, with 1 o F resolution (1 LSB in the 8-bit ADC)
Temperature Sensor Offset to Convert from K to ºC.
Temperature Sensor Trim Enable.
Temperature Sensor Trim Value.
Register 13h. Temperature Value Offset
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
tvoffs[7:0]
Type
R/W
Reset value = 00000000
Bit
7:0
Name
tvoffs[7:0]
Function
Temperature Value Offset.
This value is added to the measured temperature value. (MSB, tvoffs[8]: sign bit)
Note: If a new configuration is needed (e.g., for the WUT or the LDC), proper functionality is required.
The function must first be disabled, then the settings changed, then enabled back on.