14. Errata Status Summary
Errat
a#
Title
1
TX Current Consumption.
Some non-standard frequencies are
2
not supported.
Radio does not return to the low
3
power state when in Auto TX mode.
Potential modem failure with default
4
settings.
Default register settings for optimal
5
current consumption.
Register modification required for TX
6
data-rates greater than
100 kbps.
Wake Up Timer and Low Duty Cycle
7
mode not functional.
Impact
Major
Major
Minor
Minor
Minor
Informational
Minor
Status
Increased current consumption at +13 dBm,
other power levels unaffected.
Will be fixed in the next revision.
Will be fixed in the next revision.
Will be fixed in the next revision.
Will be fixed in the next revision.
Will update data sheet to reflect operation.
Use the micro or 32 kHz option for these
functions. Will be fixed in the next revision.
Impact Definition: Each erratum is marked with an impact, as defined below:
Minor:
Workaround exists.
Major:
Errata that do not conform to the data sheet or standard.
Information: The device behavior is acceptable the data sheet will be changed to match the device behavior.