English
Language : 

MC9S08SH32 Datasheet, PDF (62/328 Pages) Freescale Semiconductor, Inc – Microcontrollers
Chapter 5 Resets, Interrupts, and General System Control
other than the most experienced programmers because it can lead to subtle program errors that are difficult
to debug.
The interrupt service routine ends with a return-from-interrupt (RTI) instruction which restores the CCR,
A, X, and PC registers to their pre-interrupt values by reading the previously saved information from the
stack.
NOTE
For compatibility with M68HC08 devices, the H register is not
automatically saved and restored. It is good programming practice to push
H onto the stack at the start of the interrupt service routine (ISR) and restore
it immediately before the RTI that is used to return from the ISR.
If more than one interrupt is pending when the I bit is cleared, the highest priority source is serviced first
(see Table 5-2).
5.5.1 Interrupt Stack Frame
Figure 5-1 shows the contents and organization of a stack frame. Before the interrupt, the stack pointer
(SP) points at the next available byte location on the stack. The current values of CPU registers are stored
on the stack starting with the low-order byte of the program counter (PCL) and ending with the CCR. After
stacking, the SP points at the next available location on the stack which is the address that is one less than
the address where the CCR was saved. The PC value that is stacked is the address of the instruction in the
main program that would have executed next if the interrupt had not occurred.
UNSTACKING
ORDER
TOWARD LOWER ADDRESSES
7
0
51
42
33
24
15
CONDITION CODE REGISTER
ACCUMULATOR
INDEX REGISTER (LOW BYTE X)*
PROGRAM COUNTER HIGH
PROGRAM COUNTER LOW
SP AFTER
INTERRUPT STACKING
SP BEFORE
THE INTERRUPT
STACKING
ORDER
TOWARD HIGHER ADDRESSES
* High byte (H) of index register is not automatically stacked.
Figure 5-1. Interrupt Stack Frame
When an RTI instruction is executed, these values are recovered from the stack in reverse order. As part of
the RTI sequence, the CPU fills the instruction pipeline by reading three bytes of program information,
starting from the PC address recovered from the stack.
MC9S08SH32 Series Data Sheet, Rev. 2
62
Freescale Semiconductor
PRELIMINARY