DSP56853 Datasheet, PDF (484/662 Pages) Freescale Semiconductor, Inc – Digitial Signal Controller
TAP Controller
17.8.1.5 Capture Data Register (pstate = 6)
In this controller state, data may be parallel loaded into test registers selected by the current
instruction on the rising edge of TCK. If a test data register selected by the current instruction
does not have a parallel input, the register retains its previous value.
17.8.1.6 Shift Data Register (pstate = 2)
In this controller state, the Test Data register is connected between TDI and TDO. This data is
then shifted one stage towards its serial output on each rising edge of TCK. The TAP Controller
will remain in this state while TMS is held at a low. When a one is applied to TMS and a positive
edge of TCK occurs the controller will move to the Exit1-DR state.
17.8.1.7 Exit1 Data Register (pstate = 1)
This is a temporary controller state. If TMS is held high, and a rising edge is applied to TCK
while in this state causes the controller to advance to the Update-DR state. This terminates the
scanning process.
17.8.1.8 Pause Data Register (pstate = 3)
This controller state allows shifting of the Test Data register in the serial path between TDI and
TDO to be temporarily halted. All test data registers selected by the current instruction retain
their previous state unchanged. The controller remains in this state while TMS is held low. When
TMS goes high and a rising edge is applied to TCK, the controller advances to the Exit2-DR
state.
17.8.1.9 Exit2 Data Register (pstate = 0)
This is a temporary controller state. If TMS is held high, and a rising edge is applied to TCK
while it is in this state, the scanning process terminates and the TAP Controller advances to the
Update-DR state. If TMS is held low and a rising edge of TCK occurs, the controller advances to
the Shift-DR state.
17.8.1.10 Update Data Register (pstate = 5)
All boundary scan register contain a two stage data register. It isolates the shifting and capturing
of data on the peripheral from what is applied to internal logic during scan mode. This register is
the second stage, or parallel output, and it is used to apply a stimulus to internal logic. Data is
latched on the parallel output of these Test Data registers from the Shift register path on the
falling edge of TCK in the Update-DR state. On a rising edge of TCK, the controller advances to
the Select_DR state if TMS is held high or the Run-Test-Idle state If TMS is held low.
17-22
5685X Digital Signal Controller User Manual, Rev. 4
Freescale Semiconductor