Clock Generator Module (CGM)
In automatic bandwidth control mode (AUTO = 1), the lock detector
automatically switches between acquisition and tracking modes.
Automatic bandwidth control mode is used also to determine when the
VCO clock, CGMVCLK, is safe to use as the source for the base clock,
CGMOUT. See 9.6.2 PLL Bandwidth Control Register (PBWC). If PLL
interrupts are enabled, the software can wait for a PLL interrupt request
and then check the LOCK bit. If interrupts are disabled, software can poll
the LOCK bit continuously (during PLL start-up, usually) or at periodic
intervals. In either case, when the LOCK bit is set, the VCO clock is safe
to use as the source for the base clock. See 9.4.3 Base Clock Selector
Circuit. If the VCO is selected as the source for the base clock and the
LOCK bit is clear, the PLL has suffered a severe noise hit and the
software must take appropriate action, depending on the application.
(See 9.7 Interrupts for information and precautions on using interrupts).
The following conditions apply when the PLL is in automatic bandwidth
control mode:
• The ACQ bit (see 9.6.2 PLL Bandwidth Control Register
(PBWC)) is a read-only indicator of the mode of the filter. (See
9.4.2.2 Acquisition and Tracking Modes)
• The ACQ bit is set when the VCO frequency is within a certain
tolerance ∆TRK and is cleared when the VCO frequency is out of a
certain tolerance ∆UNT. (See 9.10 Acquisition/Lock Time
Specifications)
• The LOCK bit is a read-only indicator of the locked state of the
PLL.
• The LOCK bit is set when the VCO frequency is within a certain
tolerance ∆LOCK and is cleared when the VCO frequency is out of
a certain tolerance ∆UNL. (See 9.10 Acquisition/Lock Time
Specifications)
• CPU interrupts can occur if enabled (PLLIE = 1) when the PLL’s
lock condition changes, toggling the LOCK bit. (See 9.6.1 PLL
Control Register (PCTL))
The PLL also may operate in manual mode (AUTO = 0). Manual mode
is used by systems that do not require an indicator of the lock condition
for proper operation. Such systems typically operate well below fBUSMAX
MC68HC908AB32 — Rev. 1.1
Freescale Semiconductor
Clock Generator Module (CGM)
Technical Data
137