Register 21: ADC Sample Sequence Input Multiplexer Select 2 (ADCSSMUX2),
offset 0x080
This register defines the analog input configuration for each sample in a sequence executed with
Sample Sequencer 2. This register is 16-bits wide and contains information for four possible samples.
ADC Sample Sequence Input Multiplexer Select 2 (ADCSSMUX2)
Base 0x4003.8000
Offset 0x080
Type R/W, reset 0x0000.0000
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
reserved
Type RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
reserved
MUX3
reserved
MUX2
reserved
MUX1
reserved
MUX0
Type RO
R/W
R/W
R/W
RO
R/W
R/W
R/W
RO
R/W
R/W
R/W
RO
R/W
R/W
R/W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit/Field
31:15
14:12
11
10:8
7
6:4
3
2:0
Name
reserved
MUX3
reserved
MUX2
reserved
MUX1
reserved
MUX0
Type
RO
R/W
RO
R/W
RO
R/W
RO
R/W
Reset
0
0
0
0
0
0
0
0
Description
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
The MUX3 field is used during the fourth sample of a sequence executed
with the Sample Sequencer and specifies which of the analog inputs is
sampled for the analog-to-digital conversion.
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
The MUX2 field is used during the third sample of a sequence executed
with the Sample Sequencer and specifies which of the analog inputs is
sampled for the analog-to-digital conversion.
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
The MUX1 field is used during the second sample of a sequence
executed with the Sample Sequencer and specifies which of the analog
inputs is sampled for the analog-to-digital conversion.
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
The MUX0 field is used during the first sample of a sequence executed
with the Sample Sequencer and specifies which of the analog inputs is
sampled for the analog-to-digital conversion.
June 14, 2007
277