SMH4046 Datasheet, PDF (27/51 Pages) List of Unclassifed Manufacturers – Hot-Swap, Active DC Output Control (ADOCTM) Power Manager with I2C lnterface | |||
|
◁ |
CONFIGURATION REGISTERS (CONTINUED)
Register R06 âHealthy Triggers.
SMH4046
Preliminary Information
Register R06
D7 D6 D5 D4 D3 D2 D1 D0
Action
0
-
-
-
-
-
-
- Ext Temp fault does not cause a HEALTHY.
1
-
-
-
-
-
-
- Ext Temp fault causes a HEALTHY.
-
0
-
-
-
-
-
- Internal Temp fault does not cause a HEALTHY.
-
1
-
-
-
-
-
- Internal Temp fault causes a HEALTHY.
-
-
0
-
-
-
-
- CARD12V fault does not cause a HEALTHY.
-
-
1
-
-
-
-
- CARD12V fault causes a HEALTHY.
-
-
-
0
-
-
-
- CARD5V fault does not cause a HEALTHY.
-
-
-
1
-
-
-
- CARD5V fault causes a HEALTHY.
-
-
-
-
0
-
-
- CARD3V fault does not cause a HEALTHY.
-
-
-
-
1
-
-
- CARD3V fault causes a HEALTHY.
-
-
-
-
-
0
-
- VMC fault does not cause a HEALTHY.
-
-
-
-
-
1
-
- VMC fault causes a HEALTHY.
-
-
-
-
-
-
0
- VMB fault does not cause a HEALTHY.
-
-
-
-
-
-
1
- VMB fault causes a HEALTHY.
-
-
-
-
-
-
-
0 VMA fault does not cause a HEALTHY.
-
-
-
-
-
-
-
1 VMA fault causes a HEALTHY.
Register R0C â Misc Config
Register R0C
D7 D6 D5 D4 D3 D2 D1 D0
Action
0
-
-
-
-
-
-
- FPGA feature disabled.
1
-
-
-
-
-
-
- FPGA selected from register.
-
0
-
-
-
-
-
- ADOC fast convergence disabled.
-
1
-
-
-
-
-
- ADOC fast convergence enabled.
-
0
-
-
-
-
- Unused
-
0
-
-
-
-
- Unused
-
-
-
0
-
-
-
- Unused
-
-
-
0
-
-
-
- Unused
-
-
-
-
0
-
-
- VGATE charge pump not always on.
-
-
-
-
1
-
-
- VGATE charge pump always on.
-
-
-
-
-
0
-
- Channel C Trim polarity normal.
-
-
-
-
-
1
-
- Channel C Trim polarity inverse.
-
-
-
-
-
-
0
- Channel B Trim polarity normal.
-
-
-
-
-
-
1
- Channel B Trim polarity inverse.
-
-
-
-
-
-
-
0 Channel A Trim polarity normal.
-
-
-
-
-
-
-
1 Channel A Trim polarity inverse.
Summit Microelectronics, Inc
2082 1.7 08/23/04
27
|
▷ |