MA17502 Datasheet, PDF (20/30 Pages) Dynex Semiconductor – Radiation Hard MIL-STD-1750A Control Unit | |||
|
◁ |
MA17502
6.0 TIMING CHARACTERISTICS
This section provides the detailed timing specifications for
the MA17502. Figure 6 depicts the test load used to obtain
timing data. Figures 7 through 9 depict the timing waveforms
associated with various MA17502 signals. Table 7 provides
values for parameters specified in the timing waveforms. All
timing values provided in Table 7 are valid over the full military
temperature range (-55°C to +125°C), and are measured from
50% point to 50% point (50% of VDD supply voltage, unless
otherwise specified). Crosshatching in Figure 7 indicates either
a âdonât careâ or indeterminate state.
Figure 6: Test Load
Subgroup Definition
1
Static characteristics specified in Table 9 at +25°C
2
Static characteristics specified in Table 9 at +125°C
3
Static characteristics specified in Table 9 at -55°C
7
Functional tests at +25°C
8a
Functional tests at +125°C
8b
Functional tests at -55°C
9
Switching characteristics specified in Table 7b at +25°C
10
Switching characteristics specified in Table 7b at +125°C
11
Switching characteristics specified in Table 7b at -55°C
Table 7a: Definition of Subgroups
No. Parameter
Test Condition (1) (2) Min Max Units
1 CLKPC â to Microword 1 Valid
2 CLK02 â to Microword 2 Valid
3 Microword 1 after CLK02 â
4 Microword 2 after CLKPC â
5 AD Bus to CLKPC â
6 T1 to CLKPC â
7 PIF to CLKPC â
8 IR to CLKPC â
9 HOLD to CLKPC â
10 RESET to CLKPC â
11 AD Bus after CLKPC â
12 HOLD after CLKPC â
13 RESET after CLKPC â
14 T1, PlF, lR after CLKPC â
Load 1
Load 1
Load 1
Load 1
-
-
-
-
-
-
-
-
-
-
-
95
ns
-
41
ns
5
-
ns
25
-
ns
10
-
ns
20
-
ns
20
-
ns
20
-
ns
15
-
ns
15
-
ns
15
-
ns
15
-
ns
15
-
ns
0
-
ns
Mil-Std-883, Method 5005, Subgroup 9, 10, 11
Notes: 1. TA = +25°C, -55°C and +125°C tested at VDD = 4.5V and 5.5V.
2. Unless otherwise noted: VIL ⥠0.0V, VIHTTL ⤠4.0V; timing measured from 50% to 50% point.
Table 7b: Timing Parameter Values
20/30
|
▷ |