English
Language : 

CS4244 Datasheet, PDF (57/63 Pages) Cirrus Logic – 4 In/4 Out Audio CODEC with PCM and TDM Interfaces
6.17 Interrupt Mask 2 (Address 20h)
7
6
5
4
Reserved
Reserved
Reserved
Reserved
CS4244
3
MASK DAC4
CLIP
2
MASK DAC3
CLIP
1
MASK DAC2
CLIP
0
MASK DAC1
CLIP
6.17.1 DACx Clip Interrupt Mask
Allows or prevents a DACx Clip event from flagging the interrupt pin.
MASK DACx CLIP In the event of a DACx Clip event, Interrupt Pin will:
0
Be Flagged
1
Not be flagged
6.18 Interrupt Notification 1 (Address 21h) (Read Only)
7
6
TST MODE ERR SP ERR
5
CLK ERR
4
3
2
Reserved ADC4 OVFL ADC3 OVFL
1
ADC2 OVFL
0
ADC1 OVFL
6.18.1 Test Mode Error
A Test Mode Error has occurred since the last clearing of the Interrupt Notification register.
TSTMOD ERR
0
1
Since the last clearing of the Interrupt Notification Register, a Test Mode Error:
Has Not Occurred
Has Occurred
6.18.2 Serial Port Error
A Serial Port Error has occurred since the last clearing of the Interrupt Notification register.
SP ERR
0
1
Since the last clearing of the Interrupt Notification Register, a Serial Port Error:
Has Not Occurred
Has Occurred
6.18.3 Clocking Error
A Clocking Error has occurred since the last clearing of the Interrupt Notification register.
CLK ERR
0
1
Since the last clearing of the Interrupt Notification Register, a Clocking Error:
Has Not Occurred
Has Occurred
6.18.4 ADCx Overflow
An ADCx Overflow has occurred since the last clearing of the Interrupt Notification register.
ADCx OVFL
0
1
Since the last clearing of the Interrupt Notification Register, a ADCx Overflow Error:
Has Not Occurred
Has Occurred
DS900F2