TMD2725 Datasheet, PDF (4/50 Pages) ams AG – The device features advanced proximity measurement
TMD2725 − AbsoluteMaximumRatings
Absolute Maximum Ratings
Figure 5:
Absolute Maximum Ratings
Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. These are stress
ratings only. Functional operation of the device at these or any
other conditions beyond those indicated under Electrical
Characteristics is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device
reliability.
Symbol
Parameter
Min Max Units
Comments
VDD
LEDA
VIO
IIO
ISCR
ESDHBM
ESDCDM
TA
TSTRG
TBODY
RHNC
MSL
Electrical Parameters
Supply Voltage to Ground
-0.3
2.2
V
LED Voltage to PGND
-0.3
3.6
V
Digital I/O terminal voltage -0.3
3.6
V
SDA, INT Output terminal
current
-1
20
mA
Electrostatic Discharge
Input Current
(latch up immunity)
JEDEC JESD78D
± 100
mA Class II
Electrostatic Discharge
HBM JS-001-2014
± 2000
V
Electrostatic Discharge
CDM JEDEC JESD22-C101F
± 500
V
Temperature Ranges and Storage Conditions
Operating Ambient
Temperature
-30
85
°C
Storage Temperature Range -40
85
°C
Package Body Temperature
IPC/JEDEC J-STD-020
The reflow peak soldering
temperature (body temperature)
is specified according to
260
°C IPC/JEDEC J-STD-020
“Moisture/Reflow Sensitivity
Classification for Non-hermetic
Solid State Surface Mount
Devices.”
Relative Humidity
(non-condensing)
5
85
%
Moisture Sensitivity Level
3
Maximum floor life time 168 hours
Page 4
Document Feedback
ams Datasheet
[v1-11] 2016-Sep-20