English
Language : 

TMD2725 Datasheet, PDF (36/50 Pages) ams AG – The device features advanced proximity measurement
TMD2725 − RegisterDescription
Figure 51:
CALIBSTAT Register
and BINSEARCH_TARGET setting of 4 causes the PDATA value
will be approximately 15 counts. This feature is useful because
it forces PDATA result to always be above zero.
The PROX_AVG field sets the number of ADC samples that are
averaged to calculate the PDATA result.
CALIBSTAT Register (Address 0xDC)
Addr: 0xDC
Bit
Bit Name
7:1
Reserved
Default
0
0
CALIB_FINISHED
0
CALIBSTAT
Access
Bit Description
RW
Reserved
This flag indicates that calibration has
RW
finished. It can only be cleared by setting this
bit high.
Figure 52:
INTENAB Register
Addr: 0xDD
Bit
Bit Name
7
ASIEN
6
PSIEN
5
PIEN
4
AIEN
3
CIEN
2:0
Reserved
INTENAB Register (Address 0xDD)
Default
0
0
0
0
0
0
Access
RW
RW
RW
RW
RW
RW
INTENAB
Bit Description
ALS Saturation Interrupt Enable
Proximity Saturation Interrupt Enable
Proximity Interrupt Enable
ALS Interrupt Enable
Calibration Interrupt Enable
Reserved
Page 36
Document Feedback
ams Datasheet
[v1-11] 2016-Sep-20