English
Language : 

AM186EM Datasheet, PDF (90/98 Pages) List of Unclassifed Manufacturers – MICROCONTROLLER BLOCK DIAGRAM
PRELIMINARY
SWITCHING CHARACTERISTICS over COMMERCIAL operating range
Reset and Bus Hold (20 MHz and 25 MHz)
Parameter
No. Symbol
Description
Reset and Bus Hold Timing Requirements
5
tCLAV AD Address Valid Delay and BHE
15 tCLAZ AD Address Float Delay
57 tRESIN RES Setup Time
58
tHVCL HOLD Setup(a)
Reset and Bus Hold Timing Responses
62 tCLHAV HLDA Valid Delay
63 tCHCZ Command Lines Float Delay
64
tCHCV
Command Lines Valid Delay
(after Float)
Preliminary
20 MHz
25 MHz
Min Max Min Max Unit
0
25
0
20 ns
0
25
0
20 ns
10
10
ns
10
10
ns
0
25
0
20 ns
25
20 ns
25
20 ns
Note:
All timing parameters are measured at 1.5 V with 50 pF loading on CLKOUTA unless otherwise noted. All output test conditions
are with CL = 50 pF. For switching tests, VIL = 0.45 V and VIH = 2.4 V, except at X1 where VIH = VCC – 0.5 V.
a This timing must be met to guarantee recognition at the next clock.
Reset and Bus Hold (33 MHz and 40 MHz)
Parameter
No. Symbol
Description
Reset and Bus Hold Timing Requirements
5
tCLAV AD Address Valid Delay and BHE
15 tCLAZ AD Address Float Delay
57 tRESIN RES Setup Time
58
tHVCL HOLD Setup(a)
Reset and Bus Hold Timing Responses
62 tCLHAV HLDA Valid Delay
63 tCHCZ Command Lines Float Delay
64
tCHCV
Command Lines Valid Delay
(after Float)
Preliminary
33 MHz
40 MHz
Min Max Min Max Unit
0
15
0
12 ns
0
15
0
12 ns
8
5
ns
8
5
ns
0
15
0
12 ns
15
12 ns
15
12 ns
Note:
All timing parameters are measured at 1.5 V with 50 pF loading on CLKOUTA unless otherwise noted. All output test conditions
are with CL = 50 pF. For switching tests, VIL = 0.45 V and VIH = 2.4 V, except at X1 where VIH = VCC – 0.5 V.
a This timing must be met to guarantee recognition at the next clock.
90