Hardware Installation
Set-Up and Installation
Connect to the Design
Connect to the target design by performing the following steps:
1. Locate the emulation cable for the device.
CAUTION!
Wear a properly grounded wrist strap or similar ESD protection before continuing.
2. Plug the cable into the target device. Ensure that the pin 1 marking (as indicated by the red
mark on the ribbon cable) matches pin 1 on the target board.
3. Plug the other end of the cables into target pod on top of the emulator. See Figure 2-3 for
the location of the target pod.
4. Select the power source for the Z86D99 ICE chip by conï¬guring the J6 jumper. See
Table 2-2 for more information on jumper settings and Figure 2-3 for the location of the J6
jumper.
5. Select either the supplied 8MHz oscillator or the targetâs oscillator to clock the ICE chip.
See Jumper settings on page 2-10 for more information on how to configure the emulator
to use the target boards oscillator.
CAUTION!
The user can not run the emulatorâs oscillator if the target oscillator or XTAL is connected. At
this time use one of the following methods to set the ICE-chipâs clock:
⢠To use the emulators oscillator remove the targetâs oscillator and connect pin 2 to
pin 3 on the J5 jumper
⢠To Use the targetâs oscillator and connect pin 1 to pin 2 on the J5 jumper and remove
the ICEBOXâs 8 MHz oscillator located at Y1.
2â6
UM005100-IRR0400
|
▷ |