English
Language : 

XC1800 Datasheet, PDF (15/16 Pages) Xilinx, Inc – XC1800 Series of In-System
R
XC1800 Series of In-System Programmable Configuration PROMs
AC Characteristics Over Operating Condition When Cascading
RESET/OE
CE
CLK
12 TCDF
DATA
Last Bit
13 TOCK
15 TOOE
First Bit
CEO
14 TOCE
14 TOCE
99020800
Symbol
Description
Min
Max
Units
12 TCDF
13 TOCK
14 TOCE
15 TOOE
CLK to Data Float Delay2, 3
CLK to CEO Delay3
CE to CEO Delay3
RESET/OE to CEO Delay3
50
ns
30
ns
35
ns
30
ns
Notes: 1. AC test load = 50 pF
2. Float delays are measured with 5 pF AC loads. Transition is measured at +/- 200mV from steady state active levels.
3. Characterized but not 100% tested.
4. All AC parameters are measured with VIL = 0.0 V and VIH = 3.0 V.
September 17, 1999 (Version 1.3)
15