.AC Characteristics Over Operating Conditions
CE
RESET/OE
CLK
DATA
9 TSCE
TOE
2 TCE
TLC
7
1
3
TCAC
9
TSCE
10
THCE
8 THC
4
TOH
11 THOE
6 TCYC
5 TDF
4 TOH
99020801
Symbol
1
TOE
2
TCE
3
TCAC
4
TOH
5
TDF
6
TCYC
7
TLC
8
THC
9
TSCE
10 THCE
11 THOE
Description
OE to Data Delay
CE to Data Delay
CLK to Data Delay
Data Hold From CE, OE, or CLK
CE or OE to Data Float Delay2
Clock Periods
CLK Low Time3
CLK High Time3
CE Setup Time to CLK (to guarantee proper counting)
CE Hold Time to CLK (to guarantee proper counting)
OE Hold Time (guarantees counters are reset)
Min
Max
Units
30
ns
45
ns
45
ns
0
ns
50
ns
67
ns
25
ns
25
ns
25
ns
0
ns
25
ns
Notes: 1. AC test load = 50 pF
2. Float delays are measured with 5 pF AC loads. Transition is measured at +/- 200mV from steady state active levels.
3. Guaranteed by design, not tested.
4. All AC parameters are measured with VIL = 0.0 V and VIH = 3.0 V.
14