English
Language : 

W25X05CLUXIG-TR Datasheet, PDF (34/47 Pages) Winbond – 1M-BIT SERIAL FLASH MEMORY WITH 4KB SECTORS AND DUAL I/O SPI
W25X10CL
8.1.30 Read Unique ID Number (4Bh)
The Read Unique ID Number instruction accesses a factory-set read-only 64-bit number that is unique
to each W25X10CL device. The ID number can be used in conjunction with user software methods to
help prevent copying or cloning of a system. The Read Unique ID instruction is initiated by driving the
/CS pin low and shifting the instruction code “4Bh” followed by a four bytes of dummy clocks. After
which, the 64-bit ID is shifted out on the falling edge of CLK as shown in figure 24.
/CS
CLK
Mode 3
Mode 0
DI
(IO0)
DO
(IO1)
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Instruction (4Bh)
Dummy Byte 1
Dummy Byte 2
High Impedance
/CS
CLK
DI
(IO0)
DO
(IO1)
23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
Dummy Byte 3
Dummy Byte 4
* = MSB
High Impedance
63 62 61
210
* 64-bit Unique Serial Number
Mode 3
Mode 0
Figure 24. Read Unique ID Number Instruction Sequence
- 34 -
Publication Release Date: February 17, 2014
Revision G