W83697HF/F
10 CONFIGURATION REGISTER
10.1 Plug and Play Configuration
The W83697HF uses Compatible PNP protocol to access configuration registers for setting up different
types of configurations. In W83697HF, there are eleven Logical Devices (from Logical Device 0 to
Logical Device B with the exception of logical device 4 for backward compatibility) which correspond to
eleven individual functions: FDC (logical device 0), PRT (logical device 1), UART1 (logical device 2),
UART2 (logical device 3), CIR (Consumer IR, logical device 6), GPIO1 (logical device 7), GPIO5(logical
device 8),GPIO2 ~GPIO4(logical device 9), ACPI ((logical device A), and Hardware monitor (logical
device B). Each Logical Device has its own configuration registers (above CR30). Host can access
those regi sters by writing an appropriate logical device number into logical device select register at CR7.
10.2 Compatible PnP
10.2.1 Extended Function Registers
In Compatible PnP, there are two ways to enter Extended Function and read or write the configuration
registers. HEFRAS (CR26 bit 6) can be used to select one out of these two methods of entering the
Extended Function mode as follows:
HEFRAS
0
1
address and value
write 87h to the location 2Eh twice
write 87h to the location 4Eh twice
- 132 -
Publication Release Date: Feb. 2002