|
THS1206IDAR Datasheet, PDF (19/43 Pages) Texas Instruments – 12-BIT, 4 ANALOG INPUT, 6 MSPS, SIMULTANEOUS SAMPLINGANALOG TO-DIGITAL CONVERTERS | |||
|
◁ |
www.ti.com
THS1206
SLAS217H â MAY 1999 â REVISED JULY 2003#
Figure 27 shows the timing of continuous conversion mode when three analog input channels are selected. The maximum
throughput rate per channel is 2 MSPS in this mode. The data flow in the bottom of the figure shows in which order the
converted data is written into the FIFO. The timing of the DATA_AV signal shown here is for a trigger level set to 3.
Sample N
Channel 1,2,3
Sample N+1
Channel 1,2,3
AIN
tw(CONV_CLKH)
CONV_CLK
td(A)
td(Pipe)
tw(CONV_CLKL)
50%
50%
tc
Data Into
FIFO
Data Nâ2
Channel 2
Data Nâ2
Channel 3
Data Nâ1
Channel 2
td(O)
Data Nâ1
Channel 2
Data Nâ1
Channel 3
DATA_AV,
Trigger Level = 3
Sample N+2
Channel 1,2,3
Data N
Channel 1
Data N
Channel 2
Data N+1
Channel 3
td(DATA_AV)
Figure 27. Timing of Continuous Conversion Mode (3-channel operation)
Figure 28 shows the timing of continuous conversion mode when four analog input channels are selected. The maximum
throughput rate per channel is 1.5 MSPS in this mode. The data flow in the bottom of the figure shows in which order the
converted data is written into the FIFO. The timing of the DATA_AV signal shown here is for a trigger level of 4.
Sample N
Channel 1,2,3,4
AIN
tw(CONV_CLKH)
CONV_CLK
td(A)
50%
td(Pipe)
tw(CONV_CLKL)
50%
tc
Data Into
FIFO
Data Nâ2
Channel 4
Data Nâ1 Data Nâ1
Channel 1 Channel 2
Sample N+1
Channel 1,2,3,4
td(O)
Data Nâ1 Data Nâ1
Channel 3 Channel 4
Data N
Channel 1
Sample N+2
Channel 1,2,3,4
Data N
Data N
Channel 2 Channel 3
Data N
Channel 4
td(DATA_AV)
DATA_AV,
Trigger Level = 4
Figure 28. Timing of Continuous Conversion Mode (4-channel operation)
19
|
▷ |