MSP430F2619S-HT
www.ti.com
SLAS697B – MARCH 2010 – REVISED JUNE 2011
POR/Brownout Reset (BOR) – Electrical Characteristics(1) (2)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
VCC(start)
V(B_IT–)
Vhys(B_IT–)
td(BOR)
t(reset)
PARAMETER
See Figure 10
See Figure 10 through Figure 12
See Figure 10
See Figure 10
Pulse length needed at RST/NMI pin to
accepted reset internally
TEST CONDITIONS
VCC
dVCC/dt ≤ 3 V/s
dVCC/dt ≤ 3 V/s
dVCC/dt ≤ 3 V/s
2.2 V/3 V
MIN
TYP
0.7 ×
V(B_IT–)
70
130
2
MAX
1.71
210
2000
UNIT
V
V
mV
μs
μs
(1) The current consumption of the brownout module is already included in the ICC current consumption data. The voltage level V(B_IT–) +
Vhys(B_IT–
) is ≤ 1.8 V.
(2) During power up, the CPU begins code execution following a period of td(BOR) after VCC = V(B_IT–) + Vhys(B_IT–). The default DCO settings
must not be changed until VCC ≥ VCC(min), where VCC(min) is the minimum supply voltage for the desired operating frequency.
VCC
Vhys(B_IT−)
V(B_IT−)
VCC(start)
1
0
t d(BOR)
Figure 10. POR/Brownout Reset (BOR) vs Supply Voltage
Copyright © 2010–2011, Texas Instruments Incorporated
35