71M6531D_10 Datasheet, PDF (29/120 Pages) Teridian Semiconductor Corporation – Energy Meter IC
FDS 6531/6532 005
Data Sheet 71M6531D/F-71M6532D/F
Table 21: Allowed Timer/Counter Mode Combinations
Timer 1
Mode 0
Mode 1
Mode 2
Timer 0 - mode 0
Yes
Yes
Yes
Timer 0 - mode 1
Yes
Yes
Yes
Timer 0 - mode 2
Not allowed Not allowed
Yes
Table 22: TMOD Register Bit Description (SFR 0x89)
Bit
Symbol
Function
Timer/Counter 1:
TMOD[7]
If TMOD[7] is set, external input signal control is enabled for Counter 0.
external gate control. The TR1 bit in the TCON register (SFR 0x88) must
Gate
also be set in order for Counter 1 to increment.
With these settings Counter 1 is incremented on every falling edge of the
logic signal applied to one or more of the interrupt sources controlled by
the DI_RBP, DIO_R1, … DIO_RXX registers.
TMOD[6]
Selects timer or counter operation. When set to 1, a counter operation is
C/T
performed. When cleared to 0, the corresponding register will function as a
timer.
TMOD[5:4] M1:M0 Selects the mode for Timer/Counter 1 as shown in Table 20.
Timer/Counter 0:
TMOD[3]
If TMOD[3] is set, external input signal control is enabled for Counter 0.
external gate control. The TR0 bit in the TCON register (SFR 0x88) must
Gate
also be set in order for Counter 0 to increment.
With these settings Counter 0 is incremented on every falling edge of the
logic signal applied to one or more of the interrupt sources controlled by
the DI_RBP, DIO_R1, … DIO_RXX registers.
TMOD[2]
Selects timer or counter operation. When set to 1, a counter operation is
C/T
performed. When cleared to 0, the corresponding register will function as
a timer.
TMOD[1:0] M1:M0 Selects the mode for Timer/Counter 0, as shown in Table 20.
Bit
TCON[7]
TCON[6]
TCON[5]
TCON[4]
TCON[3]
TCON[2]
TCON[1]
TCON[0]
Table 23: The TCON Register Bit Functions (SFR 0x88)
Symbol
Function
The Timer 1 overflow flag is set by hardware when Timer 1 overflows.
TF1
This flag can be cleared by software and is automatically cleared when an
interrupt is processed.
TR1
Timer 1 run control bit. If cleared, Timer 1 stops.
Timer 0 overflow flag set by hardware when Timer 0 overflows. This flag
TF0
can be cleared by software and is automatically cleared when an interrupt
is processed.
TR0
Timer 0 Run control bit. If cleared, Timer 0 stops.
IE1
Interrupt 1 edge flag is set by hardware when the falling edge on external
pin int1 is observed. Cleared when an interrupt is processed.
IT1
Interrupt 1 type control bit. Selects either the falling edge or low level on
input pin to cause an interrupt.
IE0
Interrupt 0 edge flag is set by hardware when the falling edge on external
pin int0 is observed. Cleared when an interrupt is processed.
IT0
Interrupt 0 type control bit. Selects either the falling edge or low level on
input pin to cause interrupt.
v1.3
© 2005-2010 TERIDIAN Semiconductor Corporation
29