Terminal Extraction
1 Before extracting any terminals, the wire cover
must be removed, and the connector and
module must be unmated.
Perform the steps in “Wire Cover Removal.”
Perform the steps in “Unmating.”
2 Both ends of the TPA must be open (in
the pre-actuated position) before
extracting any terminals.
Insert the tip of a small flat blade
screwdriver or similar tool into the notch
at one end of the TPA; then gently pry the
end of the TPA until it raises slightly from
the housing.
Open the other end of the TPA in the
same manner.
TPA Closed
(Actuated
Position)
TPA Open
(Pre-Actuated
Position)
3 Gently lift one end of the TPA away from
the connector until it unlatches from the
connector; then stop.
Lift the other end of the TPA in the same
manner.
CAUTION
!
To avoid damage to the TPA retention
tabs, DO NOT lift one end of the TPA out
of the connector while the other end is
still latched.
Pull the TPA off of the connector, and set
it aside.
Rev D
408-8788
Notch of TPA
Continued -
8 of 13