English
Language : 

408-8788 Datasheet, PDF (2/13 Pages) TE Connectivity Ltd – EBC-440 46-Way
Terminal Insertion
1 Ensure that all terminals are properly
crimped.
Both ends of the TPA must be open (in
the pre-actuated position) before
inserting any terminals into the circuit
cavities. If necessary, open the TPA as
follows:
– Insert the tip of a small flat blade
screwdriver or similar tool into the
notch at one end of the TPA; then
gently pry the end of the TPA until it
raises slightly from the housing.
– Open the other end of the TPA in the
same manner.
TPA Closed
(Actuated
Position)
TPA Open
(Pre-Actuated
Position)
408-8788
2 Align the terminal with the appropriate circuit
cavity at the wire end of the connector. Make
sure to orient the terminal as shown.
Cavities 1 and 17
2.0mm Terminals
Stabilizer Tabs
Facing Outward
Toward Long Edge
of Connector
Stabilizer Tabs
Facing Outward
Toward Long Edge
of Connector
Rev D
Cavities 30 and 46
Continued -
2 of 13