3.6.8 Rain*
When tested as specified in 4.5.10, specimens shall function normally during the
test, and there shall be no evidence of damage detrimental to performance.
3.6.9 Salt Spray*
When tested as specified in 4.5.11, specimens shall function normally during the
test, and there shall be no evidence of damage detrimental to performance.
3.6.10 Sinusoidal Vibration. When tested as specified in 4.5.12, specimens shall function
normally during the test, and there shall be no evidence of damage detrimental to
performance.
3.6.11 Random Vibration. When tested as specified in 4.5.13, specimens shall function
normally during the test, and there shall be no evidence of damage detrimental to
performance.
3.6.12 Mechanical Shock. When tested as specified in 4.5.14, specimens shall function
normally during the test, and there shall be no evidence of damage detrimental to
performance.
3.6.13 Dust (Fine Sand)*. When tested as specified in 4.5.15, specimens shall function
normally during the test, and there shall be no evidence of damage detrimental to
performance.
3.6.14 Humidity*. When tested as specified in 4.5.16, specimens shall function normally
during the test, and there shall be no evidence of damage detrimental to
performance.
3.6.15 Fluids Resistance*. When tested as specified in 4.5.17, specimens shall meet the
insulation resistance requirement of 3.6.2, and there shall be no evidence of
damage detrimental to performance.
3.6.16 EMI Shielding Effectiveness. When specimens are tested as specified in 4.5.18,
the surface transfer impedance shall not exceed 14 milliohms per meter over the
frequency range 1 MHz to 30 MHz.
3.6.17 Post Test Examination. When visually examined as specified in 4.5.19, specimens
shall not show any evidence of damage detrimental to performance.
3.7 Product Identification
The minimal information on the label shall be the part number, the description, "Raychem",
and the FSCM code. All marking shall be in accordance with MIL-STD-130 and shall
remain legible after completion of the tests specified herein.
© 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. Company. All Rights Reserved. TE Proprietary & Confidential Information.
If this document is printed, it becomes uncontrolled. Check for latest revision.
Page 6 of 14