MIL-STD-1553B Multiplex DataBus Box Couplers and
Terminators Connectorized with D-6025 Connector
Interface
D-6021
Revision A1
25-Mar-15
4.5.15 Dust (Fine Sand) (see 3.6.13). Specimens shall be tested in accordance with MIL-
STD-202, Method 110. During this test the specimens shall be subjected to the
transmission test of 4.5.3.6.
4.5.16 Humidity (see 3.6.14). Specimens shall be tested in accordance with MIL-STD-
1344, Method 1002, Type III. The specimens shall be subjected to the transmission
test of 4.5.3.6 during the last 3 cycles of the test.
4.5.17 Fluids Resistance (see 3.6.15). The specimen shall be subjected to the test fluids
in accordance with MIL-STD-1344, Method 1016, except that Steps 4.1 and 4.4
shall be omitted.
4.5.18 EMI Shielding Effectiveness (see 3.6.16). Specimens shall be tested in accordance
with MIL-C-85485, Paragraph 4.7.24. The box couplers shall be located at
approximately the center of the test specimen, and signals shall be measured on
the bus conductors. Stub connectors shall have shielded caps. The cable type shall
be Raychem 10613 or equivalent.
4.5.19 Post Test Examination (see 3.6.17). The tested samples shall be visually examined
without magnification for any evidence of damage which could impair proper
functioning.
5.0 Preparation For Delivery
5.1 Packaging and Packing. Unless otherwise specified in the procurement document,
packaging and packing shall be in accordance with commercial practice.
5.2 Marking. Unless otherwise specified, packages shall be marked in accordance with MIL-
STD-129.
© 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. Company. All Rights Reserved. TE Proprietary & Confidential Information.
If this document is printed, it becomes uncontrolled. Check for latest revision.
Page 14 of 14