English
Language : 

D-6021 Datasheet, PDF (13/14 Pages) TE Connectivity Ltd – Multiplex DataBus Box Couplers and Terminators Connectorized with D-6025 Connector Interface
MIL-STD-1553B Multiplex DataBus Box Couplers and
Terminators Connectorized with D-6025 Connector
Interface
D-6021
Revision A1
25-Mar-15
4.5.8 Altitude Immersion (see 3.6.6). The specimens shall be tested in accordance with
MIL-STD-1344, Method 1004.1, omitting Paragraph 4.3. At least one foot of cable
attached to the mating connectors shall not be immersed in the water bath.
4.5.9
Moisture Resistance (see 3.6.7). The specimens shall be tested in accordance with
MIL-STD-202, Method 106, omitting Step 7b and Paragraph 3.6. At the end of the
test, while the specimens are still in high humidity, they shall be subjected to the
transmission test of 4.5.3.6.
4.5.10 Rain (see 3.6.8). Specimens shall be tested in accordance with MIL-STD-810,
Method 506, Procedure I. The test conditions shall be as shown in Table IV. The
test shall be conducted with rain impinging at 45 degrees upon the front, back and
end faces of the box couplers. During this test, the specimens shall be subjected to
the transmission test of 4.5.3.6.
Step
1
2
3
4
5
Table IV. Rain Test Conditions
Step
Wind
Duration
Velocity
(min)
(mph)
5
0
5
40
5
40
5
40
10
0
Rainfall
Rate
(inch/hr)
2
2
2
2
2
4.5.11 Salt Spray (see 3.6.9). Specimens shall be tested in accordance with MIL-STD-26-
2, Method 101, except, the exposure time shall be 48 hours for environment
resistant components and 1000 hours for components with 1000 hour salt spray
finish. During the last day of the test the specimens shall be subjected to the
transmission test of 4.5.3.6.
4.5.12 Sinusoidal Vibration (see 3.6.10). Specimens shall be tested in accordance with
MIL-STD-202, Method 201, except the frequency range shall be 5 to 50 Hz. During
this test, the specimens shall be subjected to the transmission test of 4.5.3.6.
4.5.13 Random Vibration (see 3.6.11). Specimens shall be tested in accordance with MIL-
STD-202, Method 214, Test Condition II, Test Letter G, for 8 hours in each of three
mutually perpendicular directions. During this test, the specimens shall be
subjected to the transmission test of 4.5.3.6.
4.5.14 Mechanical Shock (see 3.6.12). Specimens shall be tested in accordance with MIL-
STD-202, Method 213, Test Condition A. During this test the specimens shall be
subjected to the transmission test of 4.5.3.6.
© 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. Company. All Rights Reserved. TE Proprietary & Confidential Information.
If this document is printed, it becomes uncontrolled. Check for latest revision.
Page 13 of 14