English
Language : 

H3LIS100DL Datasheet, PDF (21/38 Pages) STMicroelectronics – 8-bit data output
H3LIS100DL
Digital interfaces
5.2.1
SPI read
Figure 7. SPI read protocol
&6
63&
6',
6'2
5:
06 $' $' $' $' $' $'
'2 '2 '2 '2 '2 '2 '2 '2
The SPI read command is performed with 16 clock pulses. A multiple byte read command is
performed by adding blocks of 8 clock pulses to the previous one.
bit 0: READ bit. The value is 1.
bit 1: MS bit. When 0, does not increment the address. When 1, increments the address in
multiple reads.
bit 2-7: address AD(5:0). This is the address field of the indexed register.
bit 8-15: data DO(7:0) (read mode). This is the data that is read from the device (MSB first).
bit 16-... : data DO(...-8). Further data in multiple byte reads.
Figure 8. Multiple byte SPI read protocol (2-byte example)
&6
63&
6',
6'2
5:
06 $' $' $' $' $' $'
'2 '2 '2 '2 '2 '2 '2 '2 '2'2'2'2'2'2'2 '2
DocID027504 Rev 2
21/38