SDA 9257
H1 Start Time (subaddress 07) and
H1 Stop Time (subaddress 08) (identical coding)
H1 Start and Stop Times in Relation to
Reference Time
Time
+ 4.88 µs
Number in 13.5-MHz
Clock Periods
+ 66
– (– 64) + 2*
...
...
...
Control Bits
H10N8 H10N7 H10N6 …
H10F8 H10F7 H10F6 …
1
1
0
…
...
H10N2 H10N1
H10F2 H10F1
0
0
+ 0.222 µs + 3
+ 0.148 µs + 2
...
...
– (– 1) + 2*
– (+ 0) + 2*
1
1
1
…
1
1
0
0
0
…
0
0
...
– 4.51 µs
– 4.58 µs
...
– 61
– 62
...
– (+ 63) + 2
– (+ 64) + 2*
0
0
1
…
1
1
0
1
0
…
0
0
...
– 9.26 µs
– 9.33 µs
– 125
– 126
...
– (+ 127) + 2*
0
1
1
…
1
1
– (+ 128) + 2*
1
0
0
…
0
0
...
– 13.95 µs – 189
– (+ 191) + 2*
1
0
1
…
1
1
* Due to internal delays