English
Language : 

HB28K032MM3 Datasheet, PDF (46/91 Pages) Renesas Technology Corp – MultiMediaCard 32 MByte/64 MByte/128 MByte/256 MByte/512 MByte
HB28K032/L064/J128/J256/J512MM3, HB28K032/L064/J128/J256RM3
Status
Bits Identifier
Type Value
Description
Clear condition
31 OUT_OF_RANGE E R ‘0’= no error
‘1’= error
The commands argument was out C
of allowed range for this card.
30 ADDRESS_ERROR E R X ‘0’= no error
‘1’= error
A misaligned address, which did C
not match the block length was
used in the command.
29 BLOCK_LEN_ERRO E R ‘0’= no error
R
‘1’= error
The transferred block length is not C
allowed for this card or the
number of transferred bytes does
not match the block length.
28 ERASE_SEQ_ERR E R ‘0’= no error
OR
‘1’= error
An error in the sequence of erase C
commands occurred.
27 ERASE_PARAM E X ‘0’= no error
‘1’= error
An invalid selection, groups, for C
erase.
26 WP_VIOLATION E R X ‘0’= not protected The command tried to write a C
‘1’= protected write protected block.
25 CARD_IS_LOCKED S X ‘0’= card
When set, signals that the card is A
unlocked
locked by the host.
‘1’= card locked
24 LOCK_UNLOCK_ E R X ‘0’= no error
FAILED
‘1’= error
Set when a sequence or
C
password error has been
detected in lock/unlock card
command or it there was an
attempt to access a locked card.
23 COM_CRC_ERROR E R ‘0’= no error
‘1’= error
The CRC check of the previous B
command failed.
22 ILLEGAL_COMMAN E R ‘0’= no error
Command not legal for the
B
D
‘1’= error
current state
21 CARD_ECC_FAILE E X ‘0’= success
D
‘1’= failure
Card internal ECC was applied C
but the correction of data is failed.
20 CC_ERROR
E R X ‘0’= no error
Internal card controller error
C
‘1’= error
19 ERROR
E R X ‘0’= no error
‘1’= error
A general or an unknown error C
occurred during the operation.
18 UNDERRUN
E X ‘0’= no error
‘1’= error
The card could not sustain data C
transfer in stream read mode.
17 OVERRUN
E X ‘0’= no error
‘1’= error
The card could not sustain data C
programming in stream write
mode.
Rev.0.02, Sep.15.2004, page 46 of 89