English
Language : 

HYB18H1G321AF Datasheet, PDF (37/48 Pages) Qimonda AG – GDDR3 Graphics RAM 1-Gbit GDDR3 Graphics RAM
Internet Data Sheet
5.11
HYB18H1G321AF–10/11/14
1-Gbit GDDR3
Operating Current Measurement Conditions
TABLE 21
Operating Current Measurement Conditions
Symbol Parameter/Condition
IDD0
IDD1
IDD2P
IDD2F
IDD2Q
IDD3P
IDD3N
IDD4R
IDD4W
IDD5B
IDD5D
Operating Current - One bank, Activate - Precharge
tCK=min(tCK), tRC=min(tRC)
Databus inputs are SWITCHING; Address and control inputs are SWITCHING, CS = HIGH between valid
commands.
Operating Current - One bank, Activate - Read - Precharge
One bank is accessed with tCK=min(tCK), tRC=min(tRC), CL = CL(min), Address and control inputs are SWITCHING;
CS = HIGH between valid commands. Iout=0 mA
Precharge Power-Down Standby Current
All banks idle, power-down mode, CKE is LOW, tCK=min(tCK), Data bus inputs are STABLE (HIGH).
Precharge Floating Standby Current
All banks idle; CS is HIGH, CKE is HIGH, tCK=min(tCK); Address and control inputs are SWITCHING; Data bus input
are STABLE (HIGH).
Precharge Quiet Standby Current
CS is HIGH, all banks idle, CKE is HIGH, tCK=min(tCK), Address and other control inputs STABLE (HIGH), Data
bus inputs are STABLE (HIGH).
Active Power-Down Standby Current
One bank active, CKE is LOW, Address and control inputs are STABLE (HIGH); Data bus inputs are STABLE
(HIGH); standard active power-down mode.
Active Standby Current
One bank active, CS is HIGH, CKE is HIGH, tRAS= tRAS,max, tCK=min(tCK); Address and control inputs are
SWITCHING; Data bus inputs are SWITCHING.
Operating Current - Burst Read
One bank active; Continuous read bursts, CL = CL(min); tCK=min(tCK); tRAS= tRAS,max; Address and control inputs
are SWITCHING; Iout = 0 mA.
Operating Current - Burst Write
One bank active; Continuous write bursts; tCK=min(tCK); Address and control inputs are SWITCHING; Data bus
inputs are SWITCHING.
Burst Auto Refresh Current
Refresh command at tRFC=min(tRFC); tCK=min(tCK); CKE is HIGH, CS is HIGH between all valid commands; Other
command and address inputs are SWITCHING; Data bus inputs are SWITCHING.
Distributed Auto Refresh Current
tCK=tCKmin; Refresh command every tREFI; CKE is HIGH, CS is HIGH between valid commands; Other command
and address inputs are SWITCHING; Data bus inputs are SWITCHING.
Rev. 0.92, 2007-10
37
06122007-MW7D-3G3M