English
Language : 

AMIS-49587_15 Datasheet, PDF (45/56 Pages) ON Semiconductor – Power Line Carrier Modem
AMIS−49587
7.3.5.9 MaxReceivingGain
This request is used to modify the Max Receiving Gain of the AMIS−49587. The Max Receiving Gain can be set from 1 to
42 dB by step of step 6 dB, or unlimited. The data value for the request is in the field 01 to 0F by step of 2, it indicates a Max
Receiving Gain of ((N − 1) / 2) * 6 dB; or 00, which indicates an unlimited Max Receiving Gain. The data value for the Confirm
is in the field 00 to 07, indicating a Max Receiving Gain of (N * 6) dB, or 08, which indicates an unlimited Max Receiving
Gain.
Request Format:
<STX> 0x06(Length)
0x41 (AccessDB_Request)
0x0A00
Max Receiving Gain (1 byte)
CHK
Confirm Format:
<STX> 0x06(Length)
42h (AccessDB_Confirm)
0x0A00
Max Receiving Gain (1 byte)
CHK
7.3.5.10 Repeater
This request is used to modify the repeater state of the AMIS−49587. The repeater state can be
Repeater:
0x00
No Repeater:
0x01
Request Format:
<STX> 0x06(Length)
0x41 (AccessDB_Request)
0x0B00
Repeater State (1 byte)
CHK
Confirm Format:
<STX> 0x06(Length)
0x42 (AccessDB_Confirm)
0x0B00
Repeater State (1 byte)
CHK
7.3.5.11 Frequency
This request is used to modify the values of the frequencies Fs and Fm used for the PLC communication. To calculate the
value of the data field, read paragraph Sine Wave generator.
Request Format:
<STX> 0x09(Length)
0x41 (AccessDB_Request)
0x0C00
Fs (2 bytes), Fm (2 bytes)
CHK
Confirm Format:
<STX> 0x09(Length)
0x42 (AccessDB_Confirm)
0x0C00
Fs (2 bytes), Fm (2 bytes)
CHK
7.3.5.12 TimeoutSearchInitiator
This request is used to modify the value of the timeout Search Initiator. The timeout Search Initiator is set in seconds.
Request Format:
<STX> 0x07(Length)
0x41 (AccessDB_Request)
0x1100
TO Search Initiator (2 bytes)
CHK
Confirm Format:
<STX> 0x07(Length)
0x42 (AccessDB_Confirm)
0x1100
TO Search Initiator (2 bytes)
CHK
7.3.5.13 ReadConfig
This request is used to get an echo of the configuration of the AMIS−49587.
Request Format:
<STX> 0x05(Length)
0x41 (AccessDB_Request)
0x1200 CHK
Confirm Format:
<STX> 0x29(Length)
0x42 (AccessDB_Confirm)
0x1200
7.3.5.14 Read Version Soft
This request is used to read the soft version of the AMIS−49587.
Request Format:
<STX> 0x05(Length)
0x41 (AccessDB_Request)
Current configuration (36 bytes)
CHK
0x1300 CHK
www.onsemi.com
45