English
Language : 

AMIS-49587_15 Datasheet, PDF (14/56 Pages) ON Semiconductor – Power Line Carrier Modem
AMIS−49587
4.1.5 Power−on−Reset (POR)
Table 14. POWER−ON−RESET (POR)
Parameter
Test Conditions
POR threshold
Power supply rise time
0 V to 3 V
4.1.6 Digital Outputs: TDO, CLK_OUT
Symbol
Min
Typ
Max
Unit
VPOR
1.7
2.7
V
TRPOR
1
ms
Table 15. DIGITAL OUTPUTS: TDO, CLK_OUT
Parameter
Test Conditions
Low output voltage
IXOUT = 4 mA
High output voltage
IXOUT = −4 mA
4.1.7 Digital Outputs with Open Drains: TX_ENB, TXD
Symbol
Min
Typ
VOL
VOH
0.85 VDD
Max
Unit
0.4
V
V
Table 16. DIGITAL OUTPUTS WITH OPEN DRAIN: TX_END, TXD
Parameter
Test Conditions
Symbol
Min
Typ
Max
Unit
Low output voltage
IXOUT = 4 mA
VOL
0.4
V
4.1.8 Digital Inputs: BR0, BR1
Table 17. DIGITAL INPUTS: BR0, BR1
Parameter
Low input level
Test Conditions
High input level
0 V to 3 V
Input leakage current
Symbol
Min
Typ
Max
Unit
VIL
0.2 VDD
V
VIH
0.8 VDD
V
ILEAK
−10
10
mA
4.1.9 Digital Inputs with Pulldown: TDI, TMS, TCK, TRSTB, TEST
Table 18. DIGITAL INPUTS WITH PULLDOWN: TDI, TMS, TCK, TRSTB, TEST
Parameter
Test Conditions
Symbol
Min
Typ
Max
Unit
Low input level
VIL
0.2 VDD
V
High input level
VIH
0.8 VDD
V
Pulldown resistor
(Note 14)
14. Measured around a bias point of VDD/2.
RPU
7
50
kW
4.1.10 Digital Schmitt Trigger Inputs: RXD, RESB
Table 19. DIGITAL SCHMITT TRIGGER INPUTS: RXD, RESB
Parameter
Test Conditions
Rising threshold level
Falling threshold level
Input leakage current
Symbol
Min
Typ
Max
Unit
VT+
0.8 VDD
V
VT−
0.2 VDD
V
ILEAK
−10
1−
mA
www.onsemi.com
14