English
Language : 

HAC830CV-M-A-2-A-2 Datasheet, PDF (32/49 Pages) Micronas – Robust Multi-Purpose Programmable Linear Hall-Effect Sensor with Integrated Capacitors
DATA SHEET
HAC 830
4.8. Diagnostics and Safety Features
4.8.1. Overvoltage and Undervoltage Detection
at TJ = 40 °C to +170 °C, Typical Characteristics for TJ = 25 °C, after programming and locking
Symbol Parameter
Pin Min. Typ. Max. Unit Test Conditions
No.
VSUP,UV Undervoltage detec- 1
tion level

4.2 4.5 V
1)
VSUP,OV Overvoltage detec- 1
tion level
8.5 8.9 10.0 V
1)
1) If the supply voltage drops below VSUP,UV or rises above VSUP,OV, the output voltage is switched
to VSUP (97% of VSUP at RL = 10 k to GND).
Note
The over- and undervoltage detection is activated only after locking
the sensor!
4.8.2. Open-Circuit Detection
at TJ = 40 °C to +170 °C, Typical Characteristics for TJ = 25 °C, after locking the sensor.
Symbol Parameter
Pin No. Min. Typ. Max. Unit
VOUT
Output Voltage at 3
open VSUP line
0
0
0.15 V
0
0
0.2 V
0
0
0.25 V
VOUT
Output Voltage at 3
open GND line
4.85 4.9 5.0 V
4.8 4.9 5.0 V
1) not tested
4.75 4.9 5.0 V
Comment
VSUP = 5 V
RL = 10 kto 200k
VSUP = 5 V
5 kRL < 10 k
VSUP = 5 V
4.5 kRL
<
10
k1)
VSUP = 5 V
RL = 10 kto 200k
VSUP = 5 V
5 kRL < 10 k
VSUP = 5 V
4.5 kRL
<
10
k1)
Micronas
Feb. 24, 2016; DSH000178_001EN
32