English
Language : 

HAC830CV-M-A-2-A-2 Datasheet, PDF (19/49 Pages) Micronas – Robust Multi-Purpose Programmable Linear Hall-Effect Sensor with Integrated Capacitors
DATA SHEET
HAC 830
Step 2: Initialize DSP
As the D/A-READOUT register value depends on the settings of SENSITIVITY,
VOQ and CLAMP-LOW/HIGH, these registers have to be initialized with defined val-
ues, first:
– VOQINITIAL = 2.5 V
– Clamp-Low = 0 V
– Clamp-High = 4.999 V
– SensINITIAL (see table 3-1.)
Table 3–1:
3dB Filter frequency SensINITIAL
80 Hz
0.6
500 Hz
0.39
1 kHz
0.42
2 kHz
0.83
Step 3: Define Calibration Points
The calibration points 1 and 2 can be set inside the specified range. The corresponding
values for VOUT1 and VOUT2 result from the application requirements.
Lowclampingvoltage  VOUT1,2  Highclampingvoltage
For highest accuracy of the sensor, calibration points near the minimum and maximum
input signal are recommended. The difference of the output voltage between calibration
point 1 and calibration point 2 should be more than 3.5 V.
Micronas
Feb. 24, 2016; DSH000178_001EN
19