4.6. Recommended Operating Conditions
Functional operation of the device beyond those indicated in the “Recommended Oper-
ating Conditions/Characteristics” is not implied and may result in unpredictable behav-
ior, reduce reliability and lifetime of the device.
All voltages listed are referenced to ground (GND).
Symbol Parameter
Pin No. Min. Typ. Max. Unit Condition
VSUP
Supply Voltage
1
4.5 5
5.5 V
12.4 12.5 12.6
During programming
IOUT
Continuous Output 3
Current
1.2 
1.2 mA
RL
Load Resistor
3
4.5 10 
k Can be pull-up or
pull-down resistor
(analog output only)
CL
Load Capacitance 3
0
100 1000 nF
For analog output
only.
Integrated capacitor
tolerance consid-
ered. Load capaci-
tance including
tolerance should not
exceed max. value.
NPRG
TJ
Number of EEPROM 
Programming Cycles
Junction Temperature 
Range1)


40 
40 
40 
100 cycles 0°C < Tamb < 55°C
125 °C
150 °C
170 °C
for 8000 h2)
for 2000 h2)
for 1000 h2)
TA
Ambient Temperature 
40 
150 °C
Range
1) Depends on the temperature profile of the application. Please contact Micronas for life time
calculations.
2) Time values are not cumulative