English
Language : 

HAC830CV-M-A-2-A-2 Datasheet, PDF (26/49 Pages) Micronas – Robust Multi-Purpose Programmable Linear Hall-Effect Sensor with Integrated Capacitors
DATA SHEET
HAC 830
4.5. Absolute Maximum Ratings
Stresses beyond those listed in the “Absolute Maximum Ratings” may cause permanent
damage to the device. This is a stress rating only. Functional operation of the device at
these conditions is not implied. Exposure to absolute maximum rating conditions for
extended periods will affect device reliability.
This device contains circuitry to protect the inputs and outputs against damage due to
high static voltages or electric fields; however, it is advised that normal precautions be
taken to avoid application of any voltage higher than absolute maximum-rated voltages
to this circuit.
All voltages listed are referenced to ground (GND).
Symbol
Parameter
Pin No. Min. Max.
VSUP
VSUP
VOUT
VOUT 
VSUP
IOUT
Supply Voltage
1
Supply Voltage
1
Output Voltage
3
Excess of Output Voltage 3,1
over Supply Voltage
Continuous Output Cur- 3
rent
8.5 8.5
16 16
5
16

2
10 10
tSh
VESD
Output Short Circuit Dura- 3
tion
ESD Protection1)
1
3

10
8
8
7.5 7.5
TJ
Junction Temperature
under bias2)
50 190
1) AEC-Q100-002 (100 pF and 1.5 k)
2) For 96 h - Please contact Micronas for other temperature requirements
3) No cumulated stress
Unit
V
V
V
V
mA
min
kV
°C
Condition
t < 96 h3)
t < 1 h3)
4.5.1. Storage and Shelf Life
Information related to storage conditions of Micronas sensors is included in the docu-
ment “Guidelines for the Assembly of Micronas Packages”. It gives recommendations
linked to moisture sensitivity level and long-term storage.
It is available on the Micronas website (http://www.micronas.com/en/service-center/
downloads) or on the service portal (http://service.micronas.com).
Micronas
Feb. 24, 2016; DSH000178_001EN
26