English
Language : 

N25Q256A11ESF40F Datasheet, PDF (33/87 Pages) Micron Technology – Micron Serial NOR Flash Memory
1.8V, 256Mb: Multiple I/O Serial Flash Memory
READ REGISTER and WRITE REGISTER Operations
DQ[1:0], followed by the data bytes. For quad SPI protocol, the command code is input
on DQ[3:0], followed by the data bytes.
Because register bits are volatile, change to the bits is immediate. If S# is not driven
HIGH, the command is not executed, flag status register error bits are not set, and the
write enable latch remains set to 1. Reserved bits are not affected by this command.
WRITE EXTENDED ADDRESS REGISTER Command
To initiate a WRITE EXTENDED ADDRESS REGISTER command, the WRITE ENABLE
command must be executed to set the write enable latch bit to 1. S# is driven LOW and
held LOW until the eighth bit of the last data byte has been latched in, after which it
must be driven HIGH. The command code is input on DQ0, followed by the data bytes.
For dual SPI protocol, the command code is input on DQ[1:0], followed by the data
bytes. For quad SPI protocol, the command code is input on DQ[3:0], followed by the
data bytes.
Because register bits are volatile, change to the bits is immediate. If S# is not driven
HIGH, the command is not executed, the flag status register error bits are not set, and
the write enable latch remains set to 1. Reserved bits are not affected by this command.
READ LOCK REGISTER Command
To execute the READ LOCK REGISTER command, S# is driven LOW. For extended SPI
protocol, the command code is input on DQ0, followed by address bytes that point to a
location in the sector. For dual SPI protocol, the command code is input on DQ[1:0]. For
quad SPI protocol, the command code is input on DQ[3:0]. Each address bit is latched
in during the rising edge of the clock. For extended SPI protocol, data is shifted out on
DQ1 at a maximum frequency fC during the falling edge of the clock. For dual SPI proto-
col, data is shifted out on DQ[1:0], and for quad SPI protocol, data is shifted out on
DQ[3:0]. The operation is terminated by driving S# HIGH at any time during data out-
put.
When the register is read continuously, the same byte is output repeatedly. Any READ
LOCK REGISTER command that is executed while an ERASE, PROGRAM, or WRITE cy-
cle is in progress is rejected with no affect on the cycle in progress.
Table 17: Lock Register
Note 1 applies to entire table
Bit Name
7:2 Reserved
1
Sector lock down
Settings
Description
0
Bit values are 0.
0 = Cleared (Default) Volatile bit: the device always powers-up with this bit cleared,
1 = Set
which means sector lock down and sector write lock bits can be
set.
When this bit set, neither of the lock register bits can be written
to until the next power cycle.
PDF: 09005aef846a804a
n25q_256mb_1_8V_65nm.pdf - Rev. G 2/2012 EN