English
Language : 

PIC18F23K20_10 Datasheet, PDF (402/456 Pages) Microchip Technology – 28/40/44-Pin Flash Microcontrollers with nanoWatt XLP Technology
PIC18F2XK20/4XK20
FIGURE 26-22: A/D CONVERSION TIMING
BSF ADCON0, GO
(Note 2)
131
Q4
130
A/D CLK 132
A/D DATA
9
8 7 .. . . . . 2
1
0
ADRES
ADIF
GO
SAMPLE
OLD_DATA
SAMPLING STOPPED
NEW_DATA
TCY
DONE
Note 1:
2:
If the A/D clock source is selected as RC, a time of TCY is added before the A/D clock starts.
This allows the SLEEP instruction to be executed.
This is a minimal RC delay (typically 100 ns), which also disconnects the holding capacitor from the analog input.
TABLE 26-25: A/D CONVERSION REQUIREMENTS
Param
No.
Symbol
Characteristic
Min Max Units
Conditions
130 TAD
A/D Clock Period
0.7 25.0(1) s TOSC based,
-40C to +85C
0.7
4.0(1)
s TOSC based,
+85C to +125C
1.0
4.0
s FRC mode, VDD2.0V
131 TCNV Conversion Time
12
12
TAD
(not including acquisition time) (Note 2)
132 TACQ Acquisition Time (Note 3)
1.4
—
s VDD = 3V, Rs = 50
135 TSWC Switching Time from Convert  Sample
— (Note 4)
136 TDIS Discharge Time
2
2
TAD
Legend: TBD = To Be Determined
Note 1: The time of the A/D clock period is dependent on the device frequency and the TAD clock divider.
2: ADRES register may be read on the following TCY cycle.
3: The time for the holding capacitor to acquire the “New” input voltage when the voltage changes full scale
after the conversion (VDD to VSS or VSS to VDD). The source impedance (RS) on the input channels is 50
.
4: On the following cycle of the device clock.
DS41303G-page 402