English
Language : 

DS8007A Datasheet, PDF (7/41 Pages) Maxim Integrated Products – Multiprotocol Dual Smart Card Interface
Multiprotocol Dual Smart Card Interface
AC ELECTRICAL SPECIFICATIONS—TIMING PARAMETERS FOR MULTIPLEXED
PARALLEL BUS
(VDD = 3.3V, VDDA = 3.3V, TA = +25°C, unless otherwise noted.) (Figure 1)
PARAMETER
XTAL 1 Cycle Time
ALE Pulse Width
Address Valid to ALE Low
ALE Low to RD or WR Low
RD Pulse Width
RD Low to Data Read Valid
WR/RD High to ALE High
WR Pulse Width
Data Write Valid to WR Low
SYMBOL
tCY(XTAL1)
tW(ALE)
tAVLL
t(AL-RWL)
tW(RD)
t(RL-DV)
t(RWH-AH)
tW(WR)
t(DV-WL)
CONDITIONS
Register URR
Other registers
MIN TYP
50
20
10
10
2 x tCY(XTAL1)
10
10
10
10
MAX
50
UNITS
ns
ns
ns
ns
ns
ns
ns
ns
ns
tW(ALE)
ALE
tAVLL
t(AL-RWL)
CS
D7–D0
ADDRESS
DATA
(READ)
RD
tW(RD)
t(RL-DV)
WR
Figure 1. Multiplexed Parallel Bus Timing
t(RWH-AH)
ADDRESS
t(DV-WL)
DATA
(WRITE)
tW(WR)
t(RWH-AH)
_______________________________________________________________________________________ 7