3.3 Specifications
3.3.1 Electrical
Power supply
Power consumption
Supply voltage effect
Ambient temperature range
Humidity
Accuracy
Repeatability
Linearity
Temperature effect
Operator interface
Continuous output Signal
Data entry
Display
Active
Passive
Discrete output
Range
Damping
Set point range
Adjustable differential range
Time delay
Relay output
AC
DC
Maximum remote cable length
120 VAC, 50/60 Hz (+10%, -15%)
240 VAC, 50/60 Hz (+10%, -15%)
24 VDC, (±10%)
15 VA nominal
Less than 1 pF over full range
-40° to +160° F (-40° to +71° C)
99% non-condensing (electronics)
Better than ±1.0%
±0.1%
±0.5%
±0.01%/° F ±0.018%/° C)
16-button keypad
2-line × 16-character LCD display
4–20 mA (isolated reversible max. 1000 ohms loop resistance)
4–20 mA (isolated reversible max. 1000 ohms loop resistance)
Dependent on power supply)
5 pF minimum; 50,000 pF maximum
0–90 seconds
0–50,000 pF
0.5 pF minimum
50,000 pF maximum
0–90 seconds level rising, level falling, both
10 amp @ 120/240 VAC resistive
10 amp @ 30 VDC resistive
0.5 amp @ 125 VDC resistive
Standard: 2500 feet (762 m)
Intrinsically safe: 800 feet (240 m)
50-604 Kotron Model 804 Sentinel II RF Level Transmitter