Table 2
FAILURE MODE
VOUT
None
–5V
Pin Open
Open Pin 1 (PLLIN/MODE) –5V
Open Pin 2 (FREQ)
–5V
Open Pin 3 (GND)
–5V
Open Pin 4 (SS)
–5V
Open Pin 5 (VFB)
0V
IOUT
IVIN
1A 453mA
1A 453mA
1A 453mA
1A 453mA
1A 453mA
0A 0.7mA
Open Pin 6 (ITH)
Open Pin 7 (VFBN)
–5V
1A 507mA
–6V pk 1A 502mA
Open Pin 8 (RUN)
Open Pin 9 (CAP)
Open Pin 10 (SENSE)
–5V
1A 453mA
–5V
1A 453mA
0V
0A 0.7mA
Open Pin 11 (VIN)
Open Pin 12 (GATE)
–5.4V
0V
1A 597mA
0A 0.7mA
Open Pin 13 (PGND)
Pins Shorted
Short Pins 1, 2
(PLLIN/MODE and FREQ)
Short Pins 2, 3
(FREQ and GND)
Short Pins 3, 4
(GND and SS)
Short Pins 4, 5
(SS and VFB)
Short Pins 5, 6
(VFB and ITH)
Short Pins 7, 8
(VFBN and RUN)
Short Pins 8, 9
(RUN and CAP)
Short Pins 9, 10
(CAP and SENSE)
Short Pins 10, 11
(SENSE and VIN)
Short Pins 11, 12
(VIN and GATE)
–5V
453mA
–5V
1A 453mA
–5V
1A 453mA
0V
0A 0.7mA
–1V(DC) 50mA
–3VP-P
–3.15V 625mA
9mA
181mA
5V
0A 860µA
–5V
1A 453mA
0V
0A 181mA
–5V
1A 453mA
0V
0A 29mA
f
350kHz
RECOVERY
WHEN
FAULT IS
REMOVED? BEHAVIOR
N/A Normal Operation.
350kHz
535kHz
350kHz
350kHz
0kHz
40kHz
350kHz
350kHz
350kHz
0kHz
20kHz
0kHz
350kHz
OK
Pin already left open in normal application, so no difference.
OK
Frequency jumps to default open value.
OK
Exposed pad still provides GND connection to device.
OK
External soft-start removed, but internal soft-start still available.
OK
Controller stops switching. VFB internally self biases HI to prevent
switching.
OK
Output still regulating, but the switching is erratic. Loop not stable.
OK
Use a 5.1V Zener VZ, 10k RZ and 0.01µF CZ. Output Voltage is –6V
peak and averages –4.9V.
OK
Controller does not start-up.
OK
More jitter during switching, but regulates normally.
OK
SENSE internally prebiases to 0.6V below VIN. This prevents
controller from switching.
OK
VIN able to bias internally through SENSE. Regulates with high
VOUT ripple.
OK
Gate does not drive external power FET, preventing output
regulation.
OK
Pin 3 (GND) still provides GND connection to device.
350kHz
0kHz
0kHz
Erratic
350kHz
350kHz
OK
Burst Mode operation disabled, but runs normally as in pulse-
skipping mode.
OK
FREQ already shorted to GND, so regulates normally.
OK
SS short to GND prevents device from starting up.
OK
VOUT oscillates from 0V to 3V.
OK
Controller loop does not regulate to proper output voltage.
OK
Controller does not start-up.
350kHz
0kHz
50kHz
0kHz
OK
Able to start-up and regulate normally.
OK
CAP ~ VIN, which prevents turning on external P-MOSFET.
OK
Regulates with high VOUT ripple.
OK
Power MOSFET is always kept OFF, preventing regulation.
For more information www.linear.com/3863