English
Language : 

X45620 Datasheet, PDF (9/20 Pages) Intersil Corporation – Dual Voltage Monitor with Integrated System Battery Switch and EEPROM
X45620
RESET Output Timing
Symbol
tPURST
tRPD
tRPD2
tLR
tF
tR
VRVALID
tVB1
tVB2
Parameter
RESET Time Out Period
PUP = 0
PUP = 1
VTRIP1 to RESET (Power-down only), VTRIP1 to
LOWLINE
VTRIP2 to V2FAIL
LOWLINE to RESET delay (Power-down only)
VCC/V2MON Fall Time
VCC/V2MON Rise Time
Reset Valid VCC
VBATT + 0.03 V to BATT-ON (logical 0)
VBATT – 0.03 V to BATT-ON (logical 1)
Notes: (9) This measurement is from 10% to 90% of the supply voltage.
WDT Restart Timing
Min Typ (6) Max
75
150
250
400
600
800
10
20
Unit
ms
Test Conditions
Note 4
µs
Note 4
10
20
µs
100
200
300
ns
1000
µs
1000
µs
1
V
20
µs
20
µs
Note 4
Note 4
Note 4, 9
Note 4, 9
Note 4
Note 4
SCL
tHD:STA
SDA
WDO
<tWDO
tWDO
tRST
tWDO
Minimum WDT Restart Timing
SCL
tHIGH
tLOW
tHD:STA
SDA
WDT Restart
tHIGH
tSU:STO
WDT Restart
9
FN8250.0
July 29, 2005