English
Language : 

X45620 Datasheet, PDF (4/20 Pages) Intersil Corporation – Dual Voltage Monitor with Integrated System Battery Switch and EEPROM
X45620
ABSOLUTE MAXIMUM RATINGS
Temperature under bias ................... -65°C to +135°C
Storage temperature ........................ -65°C to +150°C
Voltage on any pin with
respect to VSS ...................................... -1.0V to +6V
D.C. output current
(all output pins except VOUT)............................. 5mA
D.C. output current VOUT.................................... 50mA
Lead temperature (soldering, 10 seconds) ........ 300°C
COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only; functional operation of the
device (at these or any other conditions above those
listed in the operational sections of this specification) is
not implied. Exposure to absolute maximum rating con-
ditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
Min
0°C
-40°C
Max
70°C
+85°C
Device Option
-2.7
Blank
Supply Voltage
2.7V-5.5V
4.75V-5.5V
D.C. OPERATING CHARACTERISTICS
(Over recommended operating conditions unless otherwise specified)
Symbol
ICC1
ICC2
ICC3
IBATT1
IBATT2
VOUT1
VOUT2
VOLB
VBSH
VTRIP1
VTRIP2
Parameter
VCC Supply Current (Active)
(Excludes IOUT) Read Memory array
(Excludes IOUT) Write nonvolatile
Memory
VCC Supply Current (Passive)
(Excludes IOUT)
VCC Current (Battery Backup Mode)
(Excludes IOUT)
VBATT Current (Excludes IOUT)
VBATT Current (Excludes IOUT)
(Battery Backup Mode)
Output Voltage (VCC > VBATT + 0.03V or
VCC > VTRIP1
Output Voltage (VCC < VBATT + 0.03V
and VCC < VTRIP1) {Battery Backup}
Output (BATT-ON) LOW Voltage
Battery Switch Hysteresis
(VCC < VTRIP1)
VCC Reset Trip Point Voltage
V2MON Reset Trip Point Voltage
Limits
Min Typ (6) Max Unit Test Conditions
mA SCL = 400kHz
1.5
VOUT, RESET,
3.0
LOWLINE = Open
Note 1
µA SDA = VCC, Any Input =
50
VSS or VCC: VOUT,
RESET, LOWLINE =
Open, Note 2
1
µA VBATT = 2.8V, VOUT, RE-
SET = Open, Note 4, 1
1
µA VOUT = VCC, Note 4
50
µA VOUT = VBATT,
VBATT = 2.8V
VOUT, RESET = Open,
Note 4
VCC – 0.05
VCC – 0.5
VBATT – 0.2
VCC – 0.02 V
VCC – 0.2 V
V
IOUT = -5mA
IOUT = -50mA
IOUT = -250µA
0.4
V IOL = 3.0mA (5V)
IOL = 1.0mA (3V)
30
mV Power-up
-30
mV Power-down, Note 4
4.5
4.62
4.75
V X45620
2.55
2.62
2.7
X45620-2.7
2.55
2.62
2.7
V X45620
1.7
1.75
1.8
X45620-2.7
4
FN8250.0
July 29, 2005