ISL6112
Electrical Specifications 12VIN = 12V, 3VIN = 3.3V, VSTBY = 3.3V, TA = TJ = -40°C to +85°C, Unless Otherwise Noted. (Continued)
PARAMETER
SYMBOL
CONDITION
MIN
TYP
MAX UNITS
CFILTER OVERCURRENT DELAY TIME PINS 2 AND 35 FLOATING
CFILTER Threshold Voltage
VFILTER
1.20
1.25
1.30 V
CFILTER Charging Current
Nominal Current Limit Duration =
CCFILTER x 550k
IFILTER
VXVIN – VXSENSE > VTHILIMIT
2
2.5
3
µA
tFILTER
CFILTER Open
Current Limit Threshold Voltages
VTHILIMIT VXIN – VXVSENSE
47.5
Fast-Trip Threshold Voltages
VTHFAST VXVIN – VXVSENSE
85
XVSENSE Input Current
ISENSE
LOW-Level Input Voltage ON,
VIL
AUXEN, GPI, FORCE_ON, PRSNT
Output LOW Voltage FAULT,
PWRGD
VOL
IOL = 3mA
HIGH-Level Input Voltage ON,
VIH
2.1.
AUXEN, GPI, FORCE_ON
Internal Pull-ups to VSTBY (Note 5)
RPULL-UP
12VIN, 3VIN Input Leakage Current ILKG,OFF XVIN VSTBY = +3.3V, 12VIN = OFF; 3VIN = OFF
Input Leakage Current, ON, AUXEN,
IIL
-2
FORCE_ON
Off-State Leakage Current FAULT,
ILKG(OFF) GPI ILKG for these two pins measured with
-2
PWRGD, GPI
VAUX OFF
Over-temperature Shutdown and
Reset Thresholds, with Overcurrent
On Slot
TOV
TJ increasing, each slot (Note 5)
TJ decreasing, each slot (Note 5)
Over-temperature Shutdown and
Reset Thresholds, All Other
Conditions (All Outputs Will Latch Off)
TJ increasing, each slot (Note 5)
TJ decreasing, each slot (Note 5)
Output MOSFET Resistance VAUX
MOSFET
rDS(AUX)
IDS = 375mA
Off-State Output Offset Voltage VAUX VOFF(VAUX) VAUX = Off
Regulated Current Level
ILIM(AUX)
0.8
Output Discharge Resistance
RDIS(12V) 12VOUT = 6.0V
RDIS(3V) 3VOUT = 1.65V
RDIS(VAUX) 3VAUX = 1.65V
12V Current Limit Response Time
(See “Typical Application Diagram”
on page 9).
tOFF(12V)
CGATE = 25pF
VIN – VSENSE = 140mV
3.3V Current Limit Response Time
(See “Typical Application Diagram”
on page 9).
tOFF(3V)
CGATE = 25pF
VIN – VSENSE = 140mV
VAUX Current Limit Response Time
(See “Typical Application Diagram”
on page 9).
tSC
VAUX = 0V, VSTBY = +3.3V
Delay from MAIN Overcurrent to
FAULT Output
tPROP
CFILTER = 0
(12V FAULT or 3V VIN – VSENSE = 140mV
FAULT)
Delay from VAUX Overcurrent to
FAULT Output
tPROP
ILIM(AUX) to FAULT output CFILTER = 0
(VAUXFAULT) VAUX Output Grounded
ON, AUXEN, PRSNT Minimum Pulse
Width
tW
(Note 5)
Power-On Reset Time after VSTBY
Becomes Valid
tPOR
(Note 5)
10
50
100
0.1
40
0.5
140
130
160
150
25
1
1400
140
350
1
µs
52.5 mV
115 mV
µA
0.8
V
0.4
V
5
V
50
kΩ
1
µA
2
µA
2
µA
°C
°C
°C
°C
350 mΩ
40 mV
1.2
A
1850 Ω
180 Ω
400 Ω
2.1 µs
0.3
1
µs
2.5
µs
1
µs
1
µs
100
ns
250
µs
7
FN6456.0