English
Language : 

ISL68134_16 Datasheet, PDF (48/50 Pages) Intersil Corporation – Digital Dual Output, 7-Phase Configurable PWM
ISL68134
VOLTAGE RESET (4h)
Definition: Sets TARGET RAIL VOLTAGE to match that of the VOUT_COMMAND PMBus command.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Direct
Type: Write Only
Default Value: 00h
Units: N/A
COMMAND
VOLTAGE RESET (4h)
Format
Direct
Bit Position
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
Access
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
Function
Send all 0’s
Default Value
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
AVSBus STATUS (Eh)
Definition: Returns the device status. VDONE indicates that VOUT has reached the set point. OT Warn indicates that one or more of the
device’s measured temperatures has exceeded the over temperature warning threshold set by the OT_WARN_LIMIT PMBus command.
The device sets the AVS_SDA line low to notify the host any time a bit in this register has been set.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Bit Field
Type: R/W
Default Value: N/A
Units: N/A
COMMAND
AVSBUS STATUS (Eh)
Format
Bit Field
Bit Position
15
14
13
12
11:0
Access
R
R
R
R
R
Function
VDONE
Not Used
Not Used
OT Warn
Not Used
Default Value
N/A
0
0
N/A
0
AVSBus VERSION (Fh)
Definition: Returns the version of the AVSBus specification to which the device is compliant. This device complies with Version 1.3.
Paged or Global: Global
Data Length in Bytes: 2
Data Format: Bit Field
Type: Read Only
Default Value: 00h
Units: N/A
Submit Document Feedback 48
FN8817.0
September 28, 2016