English
Language : 

ISL68134_16 Datasheet, PDF (31/50 Pages) Intersil Corporation – Digital Dual Output, 7-Phase Configurable PWM
ISL68134
VOUT_UV_FAULT_LIMIT (44h)
Definition: Sets the VOUT undervoltage fault threshold. This fault is masked during ramp or when disabled.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Direct
Type: R/W
Default Value: 0000h (0mV)
Units: mV
Equation: VOUT_UV_FAULT_LIMIT = (Direct value)
Range: 0V to VOUT_MAX
COMMAND
VOUT_UV_FAULT_LIMIT (44h)
Format
Direct
Bit Position
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
Access
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
Two’s Complement Integer
Default Value
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
OT_FAULT_LIMIT (4Fh)
Definition: Sets the power stage over-temperature fault limit.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Direct
Type: R/W
Default Value: 007Dh (+125°C)
Units: °C
Equation: OT_FAULT_LIMIT = (Direct value)
Range: 0°C to +2000°C
COMMAND
OT_FAULT_LIMIT (4Fh)
Format
Direct
Bit Position
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
Access
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
Two’s Complement Integer
Default Value
0
0
0
0
0
0
0
0
0
1
1
1
1
1
0
1
Submit Document Feedback 31